首页 / 院系成果 / 成果详情页

Radioactive Iodine Therapy in Patients with Differentiated Thyroid Cancer: Study of External Dose Rate Attenuation Law and Individualized Patient Management  期刊论文  

  • 编号:
    b849d2f6-acd4-439f-b228-d8a920a98ac5
  • 作者:
    Li, Panli#[1,2,3]Zhang, Aimi(张艾米)#[1,2]Liu, Ye[4];Xu, Chunyuan[4];Tang, Linglin[1,2];Yuan, Hong[1,2];Liu, Qiufang[1,2,3];Wang, Xiuying[3,5];Feng, Dagan[3,5];Wang, Lisheng[3,4];Huang, Gang(黄钢)*[1,2,3,6]Song, Shaoli*[1,2,3]
  • 语种:
    英文
  • 期刊:
    THYROID ISSN:1050-7256 2019 年 29 卷 1 期 (93 - 100) ; JAN 1
  • 收录:
  • 关键词:
  • 摘要:

    Background: Therapy with radioactive iodine (I-131) is a well established treatment method for postsurgical differentiated thyroid carcinoma (DTC). A fixed discharge time is generally set, regardless of individual differences in residual body radioactivity (RBA). This study aimed to investigate the RBA of each patient to find the attenuation law and to identify underlying factors in order to predict the time point for a safe, scientifically sound discharge plan. Methods: A total of 231 DTC patients undergoing I-131 treatment were all treated with 3.7 GBq (100 mCi) of I-131. RBA was estimated by measuring the external body dose rate (EDR) at a distance of 1 m from the body surface between 0 and 72 hours after oral administration of I-131. Data from each patient were used to establish a time-EDR value (h-mu Sv/h) curve. Software was developed to predict the time when a patient's dose equivalent meets the national safety standard by including six time points between 40 and 60 hours. Several factors that might affect that time were analyzed. Results: The EDR attenuation law in patients could be described with a double exponential decay model, and the cutoff value was set as 23.3 mu Sv/h, upon which the predictive software was developed. Student's t-test showed there was no statistical difference between predicted values and the actual measured values (p > 0.05). Correlation analysis found that serum thyroglobulin, total triiodothyronine, total thyroxine, free triiodothyronine, free thyroxine, thyrotropin, 2- and 24-hour iodine uptake rate of the thyroid, scores of Tc-99m-pertechnetate thyroid scan, scores of I-131 whole-body scan, scores of ultrasound scan, and gastrointestinal residues were associated with attenuation speed. A further multiple linear regression analysis found that 24-hour iodine uptake (X-1), residual thyroid grading by I-131 whole-body scan (X-2), blood free triiodothyronine (X-3) and free thyroxine (X-4) predominantly influenced the decline of the EDR. The regression equation was ; = 2.091X(1) + 6.370X(2) + 4.529X(3) + 2.466X(4) - 8.614 (F = 44.03, p < 0.01). Conclusions: An effective and convenient method was created to measure and predict the individual safety time for discharge. This could play a significant role not only for scientific hospital discharge planning, rational use of medical resources, and better individualized management, but also in public radiation protection.

  • 推荐引用方式
    GB/T 7714:
    Li Panli,Zhang Aimi,Liu Ye, et al. Radioactive Iodine Therapy in Patients with Differentiated Thyroid Cancer: Study of External Dose Rate Attenuation Law and Individualized Patient Management [J].THYROID,2019,29(1):93-100.
  • APA:
    Li Panli,Zhang Aimi,Liu Ye,Xu Chunyuan,&Song Shaoli.(2019).Radioactive Iodine Therapy in Patients with Differentiated Thyroid Cancer: Study of External Dose Rate Attenuation Law and Individualized Patient Management .THYROID,29(1):93-100.
  • MLA:
    Li Panli, et al. "Radioactive Iodine Therapy in Patients with Differentiated Thyroid Cancer: Study of External Dose Rate Attenuation Law and Individualized Patient Management" .THYROID 29,1(2019):93-100.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:104 下载次数:0
浏览次数:104
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部